ILC Dover SCape® CO/CBRN30 Air Purifying Escape Respirator

ILC Dover SCape® CO/CBRN Respirator is the only NIOSH-approved air-purifying escape respirator with a powered ventilation system. SCape provides 30 minutes of protection from carbon monoxide, chemical, biological, radiological and nuclear contaminants. Minimum order quantities may apply.

Quantity

ILC Dover SCape Respirators are the only NIOSH-approved air-purifying escape respirators with a powered ventilation system. SCape provides 30 minutes of mission critical protection from carbon monoxide, chemical, biological, radiological and nuclear contaminants.

 

In life-threatening emergencies, SCape users have a panoramic field of view and can perform a wide range of critical tasks, such as using a cell phone or mobile radio. The system’s battery-operated blower provides positive airflow inside the respirator hood, eliminating the sense of claustrophobia, reducing panic, and allowing the wearer to stay in complete control.

Rapid Deployment

Individuals responding in emergency situations must be able to react quickly and calmly if they are going to escape and help others who may be having difficulty. The SCape CO/CBRN30 system was engineered to deploy quickly and with minimal user effort.

 

Consolidated Storage

Each SCape CO/CBRN30 respirator is stored in its own (easily opened) sealed container. All parts of the SCape respirator are integrated into one assembly. Individual respirators can be safely stored in their containers within cabinets, drawers, on shelves, or in bins for fast distribution throughout a facility.

 

Stays On

The SCape respirator uses an integral blower to provide air and keep the clear hood inflated, delivering increased protection.

 

Easy Donning

The SCape system can be donned quickly and fluidly by opening the neck dam and then drawing it over the head. Once in place, the neck dam automatically adjusts to the wearer, creating a tight, comfortable seal.

Instant Activation

The blower is activated automatically when the unit is removed from its container, so no additional steps are required for activation once SCape is in place.

 

One size

Single size unit eliminates logistics burden of using a sized product.

 

Positive Airflow

The system’s battery-operated blower provides positive airflow inside the respirator hood, eliminating the sense of claustrophobia, reducing panic, and allowing the wearer to stay in complete control.

 

Extreme Comfort

No nose-cup or mouth-bit increases comfort and ability to see the wearer’s face.

 

Panoramic View

SCape users have a panoramic field of view and can perform a wide range of critical tasks, such as using a cell phone or mobile radio.

SCape CO/CBRN30 System

Certifications/Compliance

NIOSH CBRN Air-Purifying Escape Respirator — only CAP 2 (30 minute) approved system

Shelf Life

5 yrs

Storage

Self-contained in sealed container — easily stowed in/on cabinets, drawers, shelves or bins

 

EScape Hood

Protection

Average laboratory respiratory level (LRPL) 50,000 in breathing zone vs. 2,000 NIOSH requirement

Inhalation Resistance

Average 5.1 mm H20 vs. 50 mm H20 NIOSH requirement — easy to use, easy to breathe

Material

High performance polyolefin/barrier laminate

Sizing

Universal — comfortable one-size neck seal; hood easily accommodates glasses, beards, long hair — No fit testing required

Adjustment

No nose cup or adjustment straps necessary

Visor

Clear hood and large visor—360-degree

panoramic field of view

Exhaust System

Exhaust valve regulates/maintains positive pressure within the hood

 

Blower

Material

Integral polycarbonate blower assembly with automatic actuation

Flow Rate

64 lpm clean filtered air delivered to the wearer

 

Filter

Canister

Advanced carbon layering technology incorporating catalyst and P100 particulate filtering media

Duration

30 minutes of NIOSH verified protection

Protections*

30 minute protection against carbon monoxide, plus protection against mustard (HD) vapor, mustard (HD) liquid, sarin (GB) vapor, as well as a number of chemicals, including ammonia, benzene, chloride, hydrogen cyanide, hydrogen sulfide and phosgene*

 


Item #s

ILC-6000-11300-03

       

ILC Dover SCape Chemical Performance

NIOSH Testing: System Level Agent (Smartman)

Test Agent Challenge Concentration Service Time
Mustard (HD) Vapor: 50 mg/m3 > 30
Mustard (HD) Liquid: 0.43-0.86 ml > 30
Sarin (GB) Vapor: 210 mg/m3 > 30

 

NIOSH Testing: Chemical Test Agents (Filter Gas Life)

Test Agent Challenge Concentration (ppm), (64 L/min AT 25% AND 80% RH) Allowable Breakthrough (ppm) Service Time (min)

Ammonia (NH3)

1,250 25 > 30

Cyanogen Chloride (CK)

150 2 > 30

Cyclohexane (C6H12)

1,300 10 > 30

Formaldehyde (CH2O)

250 10 > 30

Hydrogen Cyanide (HCN)

470 10 > 30

Hydrogen Sulfide (H2S)

500 / 1,500* 30 > 30

Nitrogen Dioxide (NO2)

100 1 > 30

Phosgene (COCI2)

125 1.25 > 30

Phosphine (PH3)

150 0.5 > 30

Sulfur Dioxide (SO2)

750 5 > 30

*1,500 ppm supplemental testing conducted on SCape® CO/CBRN30 at AT labs

 

Supplemental Chemical Testing

Test Agent Challenge Concentration (ppm) Allowable Breakthrough (ppm) Service Time (min)
Acetic Acid 1,000 5 > 30
Acrolein* 100 1 > 30
Acrylonitrile 1,000 10 > 30
Benzene 1,000 1 > 30
Boron Trifluride 100 5 > 30
Chlorine 1,000 5 > 30
Chlorine Dioxide 1,000 2 > 30
Fluorine 100 5 > 30
Hexane 2,000 10 > 30
Hydrogen Chloride 500 5 > 30
Hydrogen Fluoride 70 3 > 30
Nitric Acid 100 2 > 30
Toluene 1,000 10 > 30

*Testing only conducted for SCape CO/CBRN30 / Testing conducted by AJE Testing and Research, Boalsburg, PA and AT Labs, Livermore, CA

 

SCape CO/CBRN30 Carbon Monoxide (CO) Penetration Performance

CO Challenge Concentration 3600 ppm
Maximum Allowable Peak Excursion (Detected CO Levels in Parts Per Million) at 30 Minute Identified Service Life Duration 500 ppm
Resulting Maximum Peak Excursion (Detected CO Levels in ppm) < 200 ppm
 
 
CO Challenge Concentration 3600 ppm
Maximum Allowable Concentration Time (CT) (ppm-Minutes) for 30 Minute Identified Service Life Duration** 12,075
Resulting Concentration Time (CT) (ppm-Minutes) at 30 Minutes < 2000

Other Products You May Need

S.E. International Radiation Detectors – Analog
S.E. International Radiation Detectors – Analog Image
S.E. International Radiation Detectors – Digital
S.E. International Radiation Detectors – Digital Image
First Line Technology FastGrab EMS Decon Kit
First Line Technology FastGrab EMS Decon Kit Image
First Line Technology FiberTect
First Line Technology FiberTect Image