Monitor 4 and Monitor 4EC |
MC1K |
Applications / Uses |
Checking industrial gauges, such as moisture, density, or level gauges containing Cesium-137, Locating Sources, Personal protection, General surveying |
Expanded Range up to 1000 mR/hr, Linear Response needs with Energy Compensation, Checking accelerator & x-ray shielding for leakage, Checking industrial gauges; such as moisture, density, or level gauges containing Cesium-137, Locating lost sources, Personal protection, General surveying |
Detector |
Monitor 4: Halogen-quenched uncompensated GM tube with thin mica window 1.5-2.0 mg/cm2 thick. Monitor 4EC: Halogen-quenched GM tube, energy compensated sidewall 2mm tin filter. Thin mica window 1.5-2.0 mg/cm2 thick |
Energy compensated halogen-quenched GM tube |
Energy Sensitivity |
1000 CPM/mR/hr (Cs137). 4EC is the same as M4 except the energy response for gamma and x-rays through the detector sidewall is flat within +61% or -26% over the range of 40 keV to 100 keV, and within+35% or -17% over the range of 100 keV to 1.3 MeV |
Detects gamma and x-rays down to 40 keV. Response is flat from 40 keV up |
Operating Range |
0-.5, 0-5, 0-50 mR/hr
0-500, 0-5,000, 0-50,000 CPM or
0-5, 0-50, 0-500 µSv/hr (SI Scale Meter Option) |
X1 position 0 – 1 mR/hr or 0 – .01 mSv/hr
X10 position 1 – 10 mR/hr or 0 – .1 mSv/hr
X100 position 5 – 100 mR/hr or 0 – 1 mSv/hr X1000 position 50 – 1000 mR/hr or 0 – 10 mSv/hr |
Accuracy |
Typically ±15% of reading (Cs137) |
Typically ±15% of reading (Cs137) |
Display |
Analog meter holds full scale in fields as high as 100X maximum reading. CPM & mR/hr scale. Optional SI Scale Meter available |
Analog Meter holds full scale in fields as high as 100X maximum reading. CPM & mR/hr scale. Optional SI Scale Meter Available |
Audio Indicator |
Internally mounted beeper (can be turned off for silent operation) |
Internally mounted beeper (can be turned off for silent operation) |
Anti-Saturation |
Meter will hold at full scale in fields as high as 100 times the maximum reading |
Meter will hold at full scale in fields as high as 100 times the maximum reading |
Power Requirements |
9-volt alkaline (included) Approx. 2,000 hrs at background |
9-volt alkaline (included) Approx. 2,000 hrs at normal background |
Temperature Range |
-20° to 55°C (-4° to 131°F) |
-20° to 55°C (-4° to 131°F) |
Humidity Range |
10% to 70% Non-Condensing |
10% to 70% Non-Condensing |
Weight |
M4: 200 g (7.1 oz)
M4EC: 224 g (7.9 oz) |
217 g (7.7 oz)
3.5 mm headphone jack with pulse out |
Outputs |
Headphone 3.5mm jack to count to computer or datalogger |
3.5 mm headphone jack with pulse out |
Size |
209 x 71 x 50 mm (8.2 x 2.8 x 1.9 in.) |
209 x 71 x 50 mm (8.2 x 2.8 x 1.9 in.) |
Includes |
Carrying Case with Belt Clip, 9 Volt Battery |
Carrying Case with Belt Clip, 9 Volt Battery |
Options |
SI Meter Option (mR/hr with CPM scale, or, mR/hr with uSv/hr scale), Radiation Response Kit, Observer Serial Software, NIST Calibration |
Radiation Response Kit , Observer Serial Software, NIST Calibration |
Warranty |
1 year limited warranty |
1 year limited warranty |